Steps to Change Recipe

  1. Connect the Camera to the PLC using this link

Important tags and steps

  • Set the recipe number you want to use by moving it to the Camera_1:O.Data[4] register.

  • Trigger the RECIPE_SWITCH

  • Check Camera_1:I.Data[1].6 to ensure the camera is not busy before triggering the recipe switch. Use a one-shot rising edge signal Recipe_ONS to trigger the switch.

  • Latch the Recipe Switch Request, Camera_1:O.Data[0].1 to send the recipe switch request.

  • Verify Recipe Match and Acknowledgment

  • Once both conditions are met, the recipe match is confirmed.

  • Unlatch the Recipe Switch Request

Error Handling

  • After confirming the recipe match, unlatch the Camera_1:O.Data[0].1 bit to complete the recipe switch process.

  • Monitor for errors during the process.

  • If an error occurs, Camera_1:I.Data[1].1 will turn true.

Key Points

  • Camera Connection: Ensure proper connection between the camera and PLC.

  • Recipe Number: Move the desired recipe number to Camera_1:O.Data[4].

  • RECIPE_SWITCH Trigger: Use Recipe_ONS to trigger the switch while ensuring the camera is not busy (Camera_1:I.Data[1].6).

  • Latch Recipe Switch Request: Set and latch Camera_1:O.Data[0].1 for the switch request.

  • Verify Recipe and Acknowledge: Confirm match between Camera_1:I.Data[8] and Camera_1:O.Data[4] and check Camera_1:I.Data[0].2.

  • Unlatch Request: Unlatch Camera_1:O.Data[0].1 after confirmation.

  • Error Monitoring: Watch for Camera_1:I.Data[1].1 to handle any errors.